Intellipower 100-300 KVA Three-phase

Intellipower Three-phase series are, True online, Double conversion UPS Systems, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output to critical loads.

SKU: Intellipower 100-300 KVA Category:

• Output isolation transformer
• Up to 91% efficiency
• Static by-pass
• LCD front panel
• 128 events alarm memory (4000 alarms)
• RS232 and relay contacts
• Custom input and output voltage ranges
• SNMP compatible communication
• T-MON remote monitoring software
• Parallel operation up to 4 devices
• High performance at nonlinear loads
• Custom input voltage and frequency ranges
• 2 years warranty
• 10 years spare parts support
• Manufactured according to EC Directive; EN62040

3100 3120 3160 3200 3250 3300
MODEL
Power (kVA) 100
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 80
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0ºC - 40ºC
Ventilation Forced air cooling
Relative humidity < %90 (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 65 dBA
Weight without batteries (kg) 750
Dimensions (mm) HxWxD 1650x1110x810
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range)
5% (with 18 Pulse rectifier, + filter), up to 100kVA
Input power factor 0,95 - 0,98 (with 18 Pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N + 1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 120
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 96
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0ºC - 40ºC
Ventilation Forced air cooling
Relative humidity < %90 (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 65 dBA
Weight without batteries (kg) 765
Dimensions (mm) HxWxD 1650x1110x810
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range)
5% (with 18 Pulse rectifier, + filter), up to 100kVA
Input power factor 0,95 - 0,98 (with 18 Pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N + 1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 160
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 128
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0ºC - 40ºC
Ventilation Forced air cooling
Relative humidity < %90 (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 70 dBA
Weight without batteries (kg) 802
Dimensions (mm) HxWxD 1730x1195x870
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range)
5% (with 18 Pulse rectifier, + filter), up to 100kVA
Input power factor 0,95 - 0,98 (with 18 Pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N + 1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 200
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 160
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0ºC - 40ºC
Ventilation Forced air cooling
Relative humidity < %90 (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 70 dBA
Weight without batteries (kg) 970
Dimensions (mm) HxWxD 1730x1195x870
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range)
5% (with 18 Pulse rectifier, + filter), up to 100kVA
Input power factor 0,95 - 0,98 (with 18 Pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N + 1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 250
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 200
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 32
Float charging voltage 432 VDC
End of discharge voltage 320 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0ºC - 40ºC
Ventilation Forced air cooling
Relative humidity < %90 (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 70 dBA
Weight without batteries (kg) 1328
Dimensions (mm) HxWxD 1880x1565x925
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range)
5% (with 18 Pulse rectifier, + filter), up to 100kVA
Input power factor 0,95 - 0,98 (with 18 Pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N + 1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 300
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 240
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 32
Float charging voltage 432 VDC
End of discharge voltage 320 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0ºC - 40ºC
Ventilation Forced air cooling
Relative humidity < %90 (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 70 dBA
Weight without batteries (kg) 1370
Dimensions (mm) HxWxD 1880x1565x925
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range)
5% (with 18 Pulse rectifier, + filter), up to 100kVA
Input power factor 0,95 - 0,98 (with 18 Pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N + 1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.