Transformator 10-400 KVA Three-phase

The new Transformator Three-phase uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels unattainable with the old analogue technology. This technology does not only create significant increase in MTBF, but the capability of DSP to accurately manipulate signals at very high speed permits all the UPS subsystems to be controlled with greatly increased precision.

SKU: Transformator 10-400 KVA Category:

• Galvanic isolation at output
• Low input current total harmonic distortion (THD)
• High input power factor
• High efficiency up to 93,5%
• Cold start function
• Static and maintenance by-pass switch
• Output short circuit and overload protection
• External REPO switch input
• 512 events memory (512 events 45000 alarms)
• Clock and calendar (battery supported)
• Automatic battery test, remaining battery time indicator
• Temperature compensated charge system (optional)
• 2 RS232 serial ports and 12 dry contact outputs
• 3 DSP controlled modular structure
• Optional SNMP and MODBUS adaptors
• Optional graphical panel
• Optional USB flash memory
• Full digital structure
• Small footprint
• ECO mode operation (optional)
• Fewer electronic components
• Output current limiting
• Advanced diagnostics for the input
• Selectable input / output voltage / frequency / range
• Split by-pass input (second input)
• Output DC leakage protection
• Separate DSP for inverter control
• Separate DSP for the PFC
• 3 level battery protection
• High charge current capacity
• Charge / discharge current indicator
• Advanced remote control
• Manufactured according to EC Directive; EN62040
• 5 years spare parts support
• 2 years warranty

DS310T DS315T DS320T DS330T DS340T DS360T DS380T DS3100T DS3120T DS3160T DS3200T DS3250T DS3300T DS3400T
MODEL
Power (kVA) 10
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 9
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 57 dBA
Weight (kg) 187
Dimensions (mm) HxWxD Dimensions (mm) HxWxD
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 15
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 13.5
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 57 dBA
Weight (kg) 198.5
Dimensions (mm) HxWxD Dimensions (mm) HxWxD
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 20
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 18
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 62 dBA
Weight (kg) 244
Dimensions (mm) HxWxD Dimensions (mm) HxWxD
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 30
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 27
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 62 dBA
Weight (kg) 270
Dimensions (mm) HxWxD Dimensions (mm) HxWxD
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 40
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 36
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 62 dBA
Weight (kg) 393
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 60
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 54
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 64 dBA
Weight (kg) 457
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 80
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 72
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 64 dBA
Weight (kg) 536
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 100
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 90
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 68 dBA
Weight (kg) 539
Dimensions (mm) HxWxD 1770x825x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 120
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 108
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 68 dBA
Weight (kg) 595
Dimensions (mm) HxWxD 1770x825x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 160
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 144
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 68 dBA
Weight (kg) 647
Dimensions (mm) HxWxD 1770x825x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 200
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 180
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATERRIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 68 dBA
Weight (kg) 910.5
Dimensions (mm) HxWxD 1770x825x855
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 250
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 225
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 72 dBA
Weight (kg) 1150
Dimensions (mm) HxWxD 1900x1250x1055
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 300
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 270
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 72 dBA
Weight (kg) 1283
Dimensions (mm) HxWxD 1900x1250x1055
OPTIONS
Different input / output voltage Please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
(*) Depending on power and input/output conditions
MODEL
Power (kVA) 400
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (415 VAC +15%, - 25% optional)
Frequency 50Hz / 60Hz, ± 5%
Power factor ≥ 0.99
(THDI) (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N , 4 Wires, ± 10%
Voltage distortion ≤ 10%
Protection Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 360
Power factor 0.9
Voltage 380/400 VAC 3 P + N , ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% / Free running: ± 0,1%
Efficiency up to 93,5%
Crest factor 3:1
Overload protection 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD < 3% (at 100% linear load)
BATTERIES
Type VRLA AGM / GEL / NiCd
Nominal voltage ± 336 VDC (2x28 batts)
Float / End of discharge voltage ± 378 VDC / ± 280 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Soſtware (3 clients + 1 server management)
Alarm logging Standard:with time & date 512 events
Protections Power module over-temperature, Over current, Temperature high alarm
Temperature range 0ºC - 40ºC
Protection degree IP20
Relative humidity 90% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 72 dBA
Weight (kg) 1497
Dimensions (mm) HxWxD 1900x1250x1055
OPTIONS
Different input / output voltage please ask
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP ,GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units (*) Depending on power and input/output conditions

Reviews

There are no reviews yet.

Be the first to review “Transformator 10-400 KVA Three-phase”

Your email address will not be published. Required fields are marked *

Menu