Standige 10-100 KVA Three-phase

The new Standige Three-phase uses the latest DSP technology to be programmed to suit a wide variety of electrical environments without impending its performance. With the DS Power range, efficiency, reliability and functionality are enhanced to levels unattainable with the old analogue technology. This technology does not only create significant increase in MTBF, but the capability of DSP to accurately manipulate signals at very high speed permits all the UPS subsystems to be controlled with greatly increased precision.

SKU: Standige 10-100 KVA Category:

• Transformerless UPS topology
• 3 Level topology
• High input power factor
• High efficiency up to 95%
• Cold start function
• Static and maintenance by-pass switch
• Output short circuit and overload protection
• External REPO switch input
• 512 events memory (512 events 45000 alarms)
• Clock and calendar (battery supported)
• Automatic battery test, remaining battery time indicator
• Temperature compensated charge system (optional)
• 2 RS232 serial ports and 12 dry contact outputs
• 3 DSP controlled modular structure
• Optional SNMP and MODBUS adaptors
• Optional graphical panel
• Optional USB flash memory
• Full digital structure
• Small footprint
• ECO mode operation (optional)
• Fewer electronic components
• Output current limiting
• Advanced diagnostics for the input
• Selectable input / output voltage / frequency / range
• Split by-pass input (second input)
• Output DC leakage protection
• Separate DSP for inverter control
• Separate DSP for the PFC
• 3 level battery protection
• High charge current capacity
• Charge / discharge current indicator
• Advanced remote control
• Manufactured according to EC Directive; EN62040
• 5 years spare parts support
• 2 years warranty

DS310H DS315H DS320H DS330H DS340H DS360 DS380H DS3100H
MODEL
Power (kVA) 10
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 9
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery vabinet Internal
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 57 dBA
Net weight (kg) 87
Dimensions (mm) HxWxD 1040x400x815
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 15
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 13.5
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATERRY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet Internal
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 57 dBA
Net weight (kg) 87
Dimensions (mm) HxWxD 1040x400x815
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 20
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 18
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet Internal
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 57 dBA
Net weight (kg) 91
Dimensions (mm) HxWxD 1040x400x815
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 30
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 27
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet Internal
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 57 dBA
Net weight (kg) 100
Dimensions (mm) HxWxD 1040x400x815
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 40
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 36
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet Internal
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 62 dBA
Net weight (kg) 173
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 60
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 54
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet Internal
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 62 dBA
Net weight (kg) 197
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 80
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 72
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 62 dBA
Net weight (kg) 203
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors `SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units
MODEL
Power (kVA) 100
INPUT
Voltage 380/400 VAC 3P + N + G ± 20% (at 100% load) / - 40% (at 70% load)
Frequency 50Hz / 60Hz , ± 5%
Power factor (at 100% load) ≥ 0.99
THDI (*) ≤ 3%
By-pass voltage 380/400 VAC 3 Phase + N, ± 10%
Voltage distortion ≤ 10%
Protections Fuses, Voltage & Frequency tolerance, Input power limit, Phase sequency indicator
OUTPUT
Power (kW) 90
Power factor 0.9
Voltage 380/400 VAC 3P + N, ± 1% (415 VAC optional )
Frequency 50Hz / 60Hz
Frequency tolerance Line synchronized: ± 2% (adjustable) / Free running: ± 0,1%
Efficiency up to 95%
Crest factor 3:1
Overload capacity 100% - 125% load: 10 min, 125% - 150% load: 1 min, - > 150% load: by pass
Other protections Advanced short circuit, Voltage tolerance, DC balance, Regenerative load, Current limiting
Voltage THD ≤ 3% (at 100% linear load)
BATTERY
Type VRLA AGM / GEL / NiCd
Number of batteries 2x30 (±30) : 60 pieces
Charge voltage 2x405 VDC
End of discharge voltage 2x300 VDC
Battery cabinet External
Battery ambient temperature 25ºC
Protections 3 level alarms, Battery fuses, Charging current limit, Temperature compensation (optional)
Automatic testing Standard every 72 hours (adjustable)
GENERAL
Standards EN62040-1, EN62040-2, EN62040-3
User interface 4 lines LCD panel, Mimic leds, 5 vector buttons, Buzzer, Optional TFT panel
Indicators P-N voltage, P-P voltage, Current, Power, Crest Factor, Frequency, PF, Service Time
Advanced Self diagnostics, 3 maintenance time indicators, Calibration over RS232,operating hour meter
Communication 2xRS232 serial ports, 4 standard and 8 optional DRY contact alarm relays
Inputs EPO input, Interactive battery panel input, Genset input
Genset kit Standard (programmable)
Software Standard T-Mon UPS Management Software (3 clients + 1 server management)
Alarm logging Standard: with time & date 512 events
Protections Power module over-temperature, Overcurrent, Temperature high alarm
Temperature ranges 0ºC - 40ºC
Protection degree IP20
Relative humidity 95% max. (non-condensing)
Altitude < 1000m above sea level
Acoustic noise < 65 dBA
Net weight (kg) 220
Dimensions (mm) HxWxD 1440x515x855
OPTIONS
Different input / output voltage Please ask
Transformer Galvanic isolation transformer at the input & output (internal)
Software T-Mon Admin Multi UPS monitoring 10-50-100-200 clients, T-Mon Server 50-100-200 clients
Adaptors SNMP, RS485, Remote monitoring panel, MODBUS (RS485 or TCP/IP), USB Alarm Logger, TCP/IP, GSM/GPRS Modem, Comport multiplexer
Parallel operation up to 8 units

Reviews

There are no reviews yet.

Be the first to review “Standige 10-100 KVA Three-phase”

Your email address will not be published. Required fields are marked *

Menu