Netz 1–3 kVA Single-Phase (Rackmount)

Netz / Netz+ series is the new generation of small power UPS by Enertech, Both input and output are single phase and output power factor is 0.8.The efficiency of this UPS is very high, it can achieve considerable power saving and reduce total cost of ownership in result.

SKU: Netz 1–3 kVA Category:

Description

Netz / Netz+

Netz / Netz+ series is the new generation of small power UPS by Enertech, Both input and output are single phase and output power factor is 0.8.The efficiency of this UPS is very high, it can achieve considerable power saving and reduce total cost of ownerships in result.

Absolute protection

The UPS systems of the Netz / Netz+ series guarantee highest protection and highest quality of care for all kinds of applications, especially mission-critical applications such as security systems and electromedical devices, and Industrial and telecommunication processes as well.
Netz / Netz+ is an uninterruptible double converter online system of class VFI SS 111 according to IEC (EN-62040-3). The power range of Netz / Netz+ is from 1kVA to 10kVA.

Easy source

Netz / Netz+ increases efficiency and simplifies supply of the UPS by power generators.
In addition, the losses in the system and in the windings, and the corrected power factor and eliminated harmonics, which are also generated by loads and the UPS itself, has been reduced in this series.

Power continuity

Enertech has been developing for many years, several solutions to meet different requirements and solve problems in the field critical applications there.
Enertech offers adaptable High level solutions of availability, which is different plant structures and the different security levels to adjust.
Enertech produces resilient UPS systems that are capable to solve a variety of faults in components and systems compensate without any interrupt to the continuous supply of the consumer.
This is accomplished by installing redundant elements and through careful planning to remedy the general points of failure, to carry out planned maintenance and monitoring the operating and environmental parameters. The employees of the technical services are ready to give you advice and provide solutions for your projects.

Flexibility

Netz / Netz+ series is suitable for every type of application, from IT to medical units, and industrial conditions. Thanks to the large selection of options, complex systems can be implemented that ensure maximum availability of particularly critical consumers.

Battery protection system (BPS):

maximum protection of the batteries is normally achieved by the rectifier; in the event of a power failure, the UPS uses this energy source to supply its own consumers. An effective battery management system is therefore essential to ensure the desired protection in an emergency.

easy installation

Very little space is required to install Netz / Netz+. In addition, installing internal serials does not require any specialization and electrical acknowledgment, just plug in, and use the UPS backward outlets.

Special solutions

The UPS can be adapted to the specific requirements of the application. Contact our technicians, for specifications and special solutions that are not listed in the catalog.

Advanced communication

  • Compatible with SNPM for remote monitoring.
  • Advanced communication, multi-platform for all operating systems and network environments. Monitoring and shutdown through Power-Shield software is included, with SNMP protocol, for operating systems Windows 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris Linux, and other
  • The UPS is equipped with a cable for direct connection to a PC (plug and play)
  • Double serial interface RS232
  • Also there is a USB connection port for using with monitoring systems which do not have RS232 ports.

 OPTIONS

  • Emergency Power Off (EPO)
  • SNMP card for monitoring system
  • Relay Card
  • Online double conversion
  • Wide input voltage range (110~300Vac)
  • Input power factor 0.99 (With PFC)
  • Output power factor 1.0
  • Optional charging current 1A or 2A for standard unit,2A charging current is for 2 groups of inside batteries.
  • Maximum charging current 12A (Long run unit)
  • Charging current can be set by LCD (Long run unit)
  • 50Hz /  60Hz frequency converter mode
  • Emergency power off function (EPO)
  • ECO mode operation for energy saving
  • Generator compatible
  • USB + RS232 multiple communications
  • SNMP + Relay Card (Optional)
  • Smart battery charging design for optimizing battery performance
  • Support lithium battery and BMS
  • Selectable output voltage: 200,208,220,230,240Vac
  • Low priority load disconnection function
1KVA S 1KVA L 2KVA S 2KVA L 3KVA S 3KVA L
GENEREAL
Capacity (VA/Watts) 1000VA/1000W
Phase single phase with ground with
INPUT
Nominal Voltage 200/208/220/230/240Vac
Voltage Range 110VAC – 300VAC ± 5%
Input voltage Range 110~300Vac @ 60%load , 160~300Vac @ 100% load
Frequency 40~70Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power Factor 1.0
Voltage Regulation ±1%
Frequency (50/60±0.1) Hz
Crest Factor 3:1
(THDv) ≤2% THD (line load), ≤4% THD (Non-linear load)
Waveform pure Sinewave
Transfer Time Zero
EFFICIENCY
AC Mode 88%
Battery Mode 85%
BATTERY
Battery Type 12V 9AH
Numbers 2
Typical recharging time (Standard mode) 4 hours recover to 90% capacity
Charging current (max) 1A or 2A
SYSTEM FEATURES
Short circuit Hold whole system
Overheat line mode: switch to bypass; backup mode: shut down UPS immediately
Battery low Alarm and switch off
EPO (optional) shut down UPS immediately
Audible & Visual alarm line failure, Battery low, Over load, System fault
Communication USB,RS232,SNMP card (optional), Relay card (optional)
PHYSICAL
Dimension W×D×H (mm) 440*325*86.5
Net Weight (kg) 11.3
ENVIRONMENT
Operating temperature 0~40˚c
Storage temperature -25˚c~55˚c
Humidity range 20~90% RH @ 0~40˚C (Non-condensing)
Altitude <1500m
Noise level less than 50dBA at 1 Meter
STANDARD
Safety IEC/EN62040-, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
GENEREAL
Capacity (VA/Watts) 1000VA/1000W
Phase single phase with ground with
INPUT
Nominal Voltage 200/208/220/230/240Vac
Voltage Range 110VAC – 300VAC ± 5%
Input voltage Range 110~300Vac @ 60%load , 160~300Vac @ 100% load
Frequency 40~70 Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power Factor 1.0
Voltage Regulation ±1%
Frequency (50/60±0.1) Hz
Crest Factor 3:1
(THDv) ≤2% THD (line load), ≤4% THD (Non-linear load)
Waveform pure Sinewave
Transfer Time Zero
EFFICIENCY
AC Mode 88%
Battery Mode 85%
BATTERY
Battery Type -
Numbers 2-3
Typical recharging time (Standard mode) 4 hours recover to 90% capacity
Charging current (max) 12A max
SYSTEM FEATURES
Short circuit Hold whole system
Overheat line mode: switch to bypass; backup mode: shut down UPS immediately
Battery low Alarm and switch off
EPO (optional) shut down UPS immediately
Audible & Visual alarm line failure, Battery low, Over load, System fault
Communication USB,RS232,SNMP card (optional), Relay card (optional)
PHYSICAL
Dimension W×D×H (mm) 440*325*86.5
Net Weight (kg) 5.6
ENVIRONMENT
Operating temperature 0~40˚c
Storage temperature -25˚c~55˚c
Humidity range 20~90% RH @ 0~40˚C (Non-condensing)
Altitude <1500m
Noise level less than 50dBA at 1 Meter
STANDARD
Safety IEC/EN62040-, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
GENEREAL
Capacity (VA/Watts) 2000VA/2000W
Phase single phase with ground with
INPUT
Nominal Voltage 200/208/220/230/240Vac
Voltage Range 110VAC – 300VAC ± 5%
Input voltage Range 110~300Vac @ 60%load , 160~300Vac @ 100% load
Frequency 40~70 Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power Factor 1.0
Voltage Regulation ±1%
Frequency (50/60±0.1) Hz
Crest Factor 3:1
(THDv) ≤2% THD (line load), ≤4% THD (Non-linear load)
Waveform pure Sinewave
Transfer Time Zero
EFFICIENCY
AC Mode 92%
Battery Mode 88%
BATTERY
Battery Type 12V 9AH
Numbers 4
Typical recharging time (Standard mode) 4 hours recover to 90% capacity
Charging current (max) 1A or 2A
SYSTEM FEATURES
Short circuit Hold whole system
Overheat line mode: switch to bypass; backup mode: shut down UPS immediately
Battery low Alarm and switch off
EPO (optional) shut down UPS immediately
Audible & Visual alarm line failure, Battery low, Over load, System fault
Communication USB,RS232,SNMP card (optional), Relay card (optional)
PHYSICAL
Dimension W×D×H (mm) 440*460*86.5
Net Weight (kg) 10.1
ENVIRONMENT
Operating temperature 0~40˚c
Storage temperature -25˚c~55˚c
Humidity range 20~90% RH @ 0~40˚C (Non-condensing)
Altitude <1500m
Noise level less than 50dBA at 1 Meter
STANDARD
Safety IEC/EN62040-, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
GENEREAL
Capacity (VA/Watts) 2000VA/2000W
Phase single phase with ground with
INPUT
Nominal Voltage 200/208/220/230/240Vac
Voltage Range 110VAC – 300VAC ±5 %
Input voltage Range 110~300Vac @ 60%load , 160~300Vac @ 100% load
Frequency 40~70 Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power Factor 1.0
Voltage Regulation ±1%
Frequency (50/60±0.1) Hz
Crest Factor 3:1
(THDv) ≤2% THD (line load), ≤4% THD (Non-linear load)
Waveform pure Sinewave
Transfer Time Zero
EFFICIENCY
AC Mode 92%
Battery Mode 88%
BATTERY
Battery Type -
Numbers 4-6
Typical recharging time (Standard mode) 4 hours recover to 90% capacity
Charging current (max) 12A max
SYSTEM FEATURES
Short circuit Hold whole system
Overheat line mode: switch to bypass; backup mode: shut down UPS immediately
Battery low Alarm and switch off
EPO (optional) shut down UPS immediately
Audible & Visual alarm line failure, Battery low, Over load, System fault
Communication USB,RS232,SNMP card (optional), Relay card (optional)
PHYSICAL
Dimension W×D×H (mm) 440*435*86.5
Net Weight (kg) 8.3
ENVIRONMENT
Operating temperature 0~40˚c
Storage temperature -25˚c~55˚c
Humidity range 20~90% RH @ 0~40˚C (Non-condensing)
Altitude <1500m
Noise level less than 50dBA at 1 Meter
STANDARD
Safety IEC/EN62040-, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
GENEREAL
Capacity (VA/Watts) 3000VA/3000W
Phase single phase with ground with
INPUT
Nominal Voltage 200/208/220/230/240Vac
Voltage Range 110VAC – 300VAC ± 5%
Input voltage Range 110~300Vac @ 60%load , 160~300Vac @ 100% load
Frequency 40~70 Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power Factor 1.0
Voltage Regulation ±1%
Frequency (50/60±0.1) Hz
Crest Factor 3:1
(THDv) ≤2% THD (line load), ≤4% THD (Non-linear load)
Waveform pure Sinewave
Transfer Time Zero
EFFICIENCY
AC Mode 92%
Battery Mode 90%
BATTERY
Battery Type 12V 9AH
Numbers 6
Typical recharging time (Standard mode) 4 hours recover to 90% capacity
Charging current (max) 1A or 2A
SYSTEM FEATURES
Short circuit Hold whole system
Overheat line mode: switch to bypass; backup mode: shut down UPS immediately
Battery low Alarm and switch off
EPO (optional) shut down UPS immediately
Audible & Visual alarm line failure, Battery low, Over load, System fault
Communication USB,RS232,SNMP card (optional), Relay card (optional)
PHYSICAL
Dimension W×D×H (mm) 440*600*86.5
440*460*131
Net Weight (kg) 26.2
25.8
ENVIRONMENT
Operating temperature 0~40˚c
Storage temperature -25˚c~55˚c
Humidity range 20~90% RH @ 0~40˚C (Non-condensing)
Altitude <1500m
Noise level less than 50dBA at 1 Meter
STANDARD
Safety IEC/EN62040-, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8
GENEREAL
Capacity (VA/Watts) 3000VA/3000W
Phase single phase with ground with
INPUT
Nominal Voltage 200/208/220/230/240Vac
Voltage Range 110VAC – 300VAC ± 5%
Input voltage Range 110~300Vac @ 60%load , 160~300Vac @ 100% load
Frequency 40~70 Hz
Power factor 0.99
Generator input Support
OUTPUT
Output voltage 200/208/220/230/240Vac
Power Factor 1.0
Voltage Regulation ±1%
Frequency (50/60±0.1) Hz
Crest Factor 3:1
(THDv) ≤2% THD (line load), ≤4% THD (Non-linear load)
Waveform pure Sinewave
Transfer Time Zero
EFFICIENCY
AC Mode 92%
Battery Mode 90%
BATTERY
Battery Type -
Numbers 6-8
Typical recharging time (Standard mode) 4 hours recover to 90% capacity
Charging current (max) 12A max
SYSTEM FEATURES
Short circuit Hold whole system
Overheat line mode: switch to bypass; backup mode: shut down UPS immediately
Battery low Alarm and switch off
EPO (optional) shut down UPS immediately
Audible & Visual alarm line failure, Battery low, Over load, System fault
Communication USB,RS232,SNMP card (optional), Relay card (optional)
PHYSICAL
Dimension W×D×H (mm) 440*435*86.5
Net Weight (kg) 8.6
ENVIRONMENT
Operating temperature 0~40˚c
Storage temperature -25˚c~55˚c
Humidity range 20~90% RH @ 0~40˚C (Non-condensing)
Altitude <1500m
Noise level less than 50dBA at 1 Meter
STANDARD
Safety IEC/EN62040-, IEC/EN60950-1
EMC IEC/EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8