Intellipower 10-80 KVA Three-phase

Intellipower Three-phase series are, True online, Double conversion UPS Systems, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output to critical loads.

SKU: Intellipower 10-80 KVA Category:

• Output isolation transformer
• Up to 91% efficiency
• Static by-pass
• LCD front panel
• 128 events alarm memory (4000 alarms)
• RS232 and relay contacts
• Custom input and output voltage ranges
• SNMP compatible communication
• T-MON remote monitoring software
• Parallel operation up to 4 devices
• High performance at nonlinear loads
• Custom input voltage and frequency ranges
• 2 years warranty
• 10 years spare parts support
• Manufactured according to EC Directive; EN62040

310 315 320 330 340 360 380
MODEL
Power (kVA) 10
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 8
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 89-91%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise < 56 dBA
Weight without batteries (kg) 220
Dimensions (mm) HxWxD 1150x505x655
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 15
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 12
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 89-91%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise < 56 dBA
Weight without batteries (kg) 260
Dimensions (mm) HxWxD 1150x505x655
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 20
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 16
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 89-91%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise < 56 dBA
Weight without batteries (kg) 284
Dimensions (mm) HxWxD 1150x505x655
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 30
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 24
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise < 56 dBA
Weight without batteries (kg) 305
Dimensions (mm) HxWxD 1150x505x655
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 40
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 32
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise 404
Dimensions (mm) HxWxD 1390x575x820
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 60
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 48
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise < 60 dBA
Weight without batteries (kg) 496
Dimensions (mm) HxWxD 1390x575x820
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)
(*): In 18Pulse & 12Pulse applications, the standard chassis dimensions may change.
MODEL
Power (kVA) 80
INPUT
Voltage 380/400 VAC 3P + N + G ± 15%
By-pass voltage 380/400 VAC 3P + N ± 10%
Input frequency 50Hz (60Hz on request) ± 5%
OUTPUT
Power (kW) 64
Power factor 0,8
Voltage 380/400 VAC 3P + N
Voltage stability Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5%
Voltage recovery time After step load: max. 25ms
Frequency 50Hz (60Hz on request)
Frequency tolerance Line synchronized: ± 2% , free running: ± 0,2%
Efficiency (at 100% load) 90-92%
Crest factor 3:1
Overload protection 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass
Short circuit protection Electronic short circuit protection
Voltage THD Linear load: < 3%
Non linear load: < 5%
BATTERIES
Type Sealed Lead Acid - Maintenance Free
Number of batteries 30
Float charging voltage 405 VDC
End of discharge voltage 300 VDC
Battery ambient temperature 25ºC
Battery protection Automatic circuit breaker
Battery test Automatic every 72 hours
GENERAL
Standards EN 62040-1,EN62040-2
Serial communication Dry contacts & RS232
Software T-Mon UPS Management Software (3 clients, +1 server management std.)
Temperature range 0°C - 40°C
Ventilation Forced air cooling
Relative humidity < 90% (non-condensing)
Protection degree IP20
Altitude < 2000m above sea level
Acoustic noise < 60 dBA
Weight without batteries (kg) 580
Dimensions (mm) HxWxD 1450x720x820
OPTIONS
Different input / output voltage Please ask
Input transformer Galvanic isolation transformer at the input (in external cabinet)
Input THD 10% (with 12 pulse or 18 pulse rectifier, according to UPS range)
%5 (with 18 pulse rectifier, + filter), up to 100kVA
Input power factor 0.95 - 0.98 (with 18 pulse rectifier)
Adaptors SNMP, MODBUS, Remote Mon. Panel, RS485
Parallel operation N+1 (up to 4 units)