• Output isolation transformer
• Up to 91% efficiency
• Static by-pass
• LCD front panel
• 128 events alarm memory (4000 alarms)
• RS232 and relay contacts
• Custom input and output voltage ranges
• SNMP compatible communication
• T-MON remote monitoring software
• Parallel operation up to 4 devices
• High performance at nonlinear loads
• Custom input voltage and frequency ranges
• 2 years warranty
• 10 years spare parts support
• Manufactured according to EC Directive; EN62040
Intellipower 100-300 KVA Three-phase
Intellipower Three-phase series are, True online, Double conversion UPS Systems, manufactured with the state of the art, PWM and IGBT technology, producing microprocessor controlled pure sinewave output to critical loads.
3100
3120
3160
3200
3250
3300
MODEL
Power (kVA) | 100 |
INPUT
Voltage | 380/400 VAC 3P + N + G ± 15% |
By-pass voltage | 380/400 VAC 3P + N ± 10% |
Input frequency | 50Hz (60Hz on request) ± 5% |
OUTPUT
Power (kW) | 80 |
Power factor | 0,8 |
Voltage | 380/400 VAC 3P + N |
Voltage stability | Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5% |
Voltage recovery time | After step load: max. 25ms |
Frequency | 50Hz (60Hz on request) |
Frequency tolerance | Line synchronized: ± 2% , free running: ± 0,2% |
Efficiency (at 100% load) | 90-92% |
Crest factor | 3:1 |
Overload protection | 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass |
Short circuit protection | Electronic short circuit protection |
Voltage THD | Linear load: < 3% Non linear load: < 5% |
BATTERIES
Type | Sealed Lead Acid - Maintenance Free |
Number of batteries | 30 |
Float charging voltage | 405 VDC |
End of discharge voltage | 300 VDC |
Battery ambient temperature | 25ºC |
Battery protection | Automatic circuit breaker |
Battery test | Automatic every 72 hours |
GENERAL
Standards | EN 62040-1,EN62040-2 |
Serial communication | Dry contacts & RS232 |
Software | T-Mon UPS Management Software (3 clients, +1 server management std.) |
Temperature range | 0ºC - 40ºC |
Ventilation | Forced air cooling |
Relative humidity | < %90 (non-condensing) |
Protection degree | IP20 |
Altitude | < 2000m above sea level |
Acoustic noise | 65 dBA |
Weight without batteries (kg) | 750 |
Dimensions (mm) HxWxD | 1650x1110x810 |
OPTIONS
Different input / output voltage | Please ask |
Input transformer | Galvanic isolation transformer at the input (in external cabinet) |
Input THD | 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range) 5% (with 18 Pulse rectifier, + filter), up to 100kVA |
Input power factor | 0,95 - 0,98 (with 18 Pulse rectifier) |
Adaptors | SNMP, MODBUS, Remote Mon. Panel, RS485 |
Parallel operation | N + 1 (up to 4 units) |
(*): | In 18Pulse & 12Pulse applications, the standard chassis dimensions may change. |
MODEL
Power (kVA) | 120 |
INPUT
Voltage | 380/400 VAC 3P + N + G ± 15% |
By-pass voltage | 380/400 VAC 3P + N ± 10% |
Input frequency | 50Hz (60Hz on request) ± 5% |
OUTPUT
Power (kW) | 96 |
Power factor | 0,8 |
Voltage | 380/400 VAC 3P + N |
Voltage stability | Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5% |
Voltage recovery time | After step load: max. 25ms |
Frequency | 50Hz (60Hz on request) |
Frequency tolerance | Line synchronized: ± 2% , free running: ± 0,2% |
Efficiency (at 100% load) | 90-92% |
Crest factor | 3:1 |
Overload protection | 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass |
Short circuit protection | Electronic short circuit protection |
Voltage THD | Linear load: < 3% Non linear load: < 5% |
BATTERIES
Type | Sealed Lead Acid - Maintenance Free |
Number of batteries | 30 |
Float charging voltage | 405 VDC |
End of discharge voltage | 300 VDC |
Battery ambient temperature | 25ºC |
Battery protection | Automatic circuit breaker |
Battery test | Automatic every 72 hours |
GENERAL
Standards | EN 62040-1,EN62040-2 |
Serial communication | Dry contacts & RS232 |
Software | T-Mon UPS Management Software (3 clients, +1 server management std.) |
Temperature range | 0ºC - 40ºC |
Ventilation | Forced air cooling |
Relative humidity | < %90 (non-condensing) |
Protection degree | IP20 |
Altitude | < 2000m above sea level |
Acoustic noise | 65 dBA |
Weight without batteries (kg) | 765 |
Dimensions (mm) HxWxD | 1650x1110x810 |
OPTIONS
Different input / output voltage | Please ask |
Input transformer | Galvanic isolation transformer at the input (in external cabinet) |
Input THD | 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range) 5% (with 18 Pulse rectifier, + filter), up to 100kVA |
Input power factor | 0,95 - 0,98 (with 18 Pulse rectifier) |
Adaptors | SNMP, MODBUS, Remote Mon. Panel, RS485 |
Parallel operation | N + 1 (up to 4 units) |
(*): | In 18Pulse & 12Pulse applications, the standard chassis dimensions may change. |
MODEL
Power (kVA) | 160 |
INPUT
Voltage | 380/400 VAC 3P + N + G ± 15% |
By-pass voltage | 380/400 VAC 3P + N ± 10% |
Input frequency | 50Hz (60Hz on request) ± 5% |
OUTPUT
Power (kW) | 128 |
Power factor | 0,8 |
Voltage | 380/400 VAC 3P + N |
Voltage stability | Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5% |
Voltage recovery time | After step load: max. 25ms |
Frequency | 50Hz (60Hz on request) |
Frequency tolerance | Line synchronized: ± 2% , free running: ± 0,2% |
Efficiency (at 100% load) | 90-92% |
Crest factor | 3:1 |
Overload protection | 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass |
Short circuit protection | Electronic short circuit protection |
Voltage THD | Linear load: < 3% Non linear load: < 5% |
BATTERIES
Type | Sealed Lead Acid - Maintenance Free |
Number of batteries | 30 |
Float charging voltage | 405 VDC |
End of discharge voltage | 300 VDC |
Battery ambient temperature | 25ºC |
Battery protection | Automatic circuit breaker |
Battery test | Automatic every 72 hours |
GENERAL
Standards | EN 62040-1,EN62040-2 |
Serial communication | Dry contacts & RS232 |
Software | T-Mon UPS Management Software (3 clients, +1 server management std.) |
Temperature range | 0ºC - 40ºC |
Ventilation | Forced air cooling |
Relative humidity | < %90 (non-condensing) |
Protection degree | IP20 |
Altitude | < 2000m above sea level |
Acoustic noise | 70 dBA |
Weight without batteries (kg) | 802 |
Dimensions (mm) HxWxD | 1730x1195x870 |
OPTIONS
Different input / output voltage | Please ask |
Input transformer | Galvanic isolation transformer at the input (in external cabinet) |
Input THD | 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range) 5% (with 18 Pulse rectifier, + filter), up to 100kVA |
Input power factor | 0,95 - 0,98 (with 18 Pulse rectifier) |
Adaptors | SNMP, MODBUS, Remote Mon. Panel, RS485 |
Parallel operation | N + 1 (up to 4 units) |
(*): | In 18Pulse & 12Pulse applications, the standard chassis dimensions may change. |
MODEL
Power (kVA) | 200 |
INPUT
Voltage | 380/400 VAC 3P + N + G ± 15% |
By-pass voltage | 380/400 VAC 3P + N ± 10% |
Input frequency | 50Hz (60Hz on request) ± 5% |
OUTPUT
Power (kW) | 160 |
Power factor | 0,8 |
Voltage | 380/400 VAC 3P + N |
Voltage stability | Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5% |
Voltage recovery time | After step load: max. 25ms |
Frequency | 50Hz (60Hz on request) |
Frequency tolerance | Line synchronized: ± 2% , free running: ± 0,2% |
Efficiency (at 100% load) | 90-92% |
Crest factor | 3:1 |
Overload protection | 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass |
Short circuit protection | Electronic short circuit protection |
Voltage THD | Linear load: < 3% Non linear load: < 5% |
BATTERIES
Type | Sealed Lead Acid - Maintenance Free |
Number of batteries | 30 |
Float charging voltage | 405 VDC |
End of discharge voltage | 300 VDC |
Battery ambient temperature | 25ºC |
Battery protection | Automatic circuit breaker |
Battery test | Automatic every 72 hours |
GENERAL
Standards | EN 62040-1,EN62040-2 |
Serial communication | Dry contacts & RS232 |
Software | T-Mon UPS Management Software (3 clients, +1 server management std.) |
Temperature range | 0ºC - 40ºC |
Ventilation | Forced air cooling |
Relative humidity | < %90 (non-condensing) |
Protection degree | IP20 |
Altitude | < 2000m above sea level |
Acoustic noise | 70 dBA |
Weight without batteries (kg) | 970 |
Dimensions (mm) HxWxD | 1730x1195x870 |
OPTIONS
Different input / output voltage | Please ask |
Input transformer | Galvanic isolation transformer at the input (in external cabinet) |
Input THD | 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range) 5% (with 18 Pulse rectifier, + filter), up to 100kVA |
Input power factor | 0,95 - 0,98 (with 18 Pulse rectifier) |
Adaptors | SNMP, MODBUS, Remote Mon. Panel, RS485 |
Parallel operation | N + 1 (up to 4 units) |
(*): | In 18Pulse & 12Pulse applications, the standard chassis dimensions may change. |
MODEL
Power (kVA) | 250 |
INPUT
Voltage | 380/400 VAC 3P + N + G ± 15% |
By-pass voltage | 380/400 VAC 3P + N ± 10% |
Input frequency | 50Hz (60Hz on request) ± 5% |
OUTPUT
Power (kW) | 200 |
Power factor | 0,8 |
Voltage | 380/400 VAC 3P + N |
Voltage stability | Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5% |
Voltage recovery time | After step load: max. 25ms |
Frequency | 50Hz (60Hz on request) |
Frequency tolerance | Line synchronized: ± 2% , free running: ± 0,2% |
Efficiency (at 100% load) | 90-92% |
Crest factor | 3:1 |
Overload protection | 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass |
Short circuit protection | Electronic short circuit protection |
Voltage THD | Linear load: < 3% Non linear load: < 5% |
BATTERIES
Type | Sealed Lead Acid - Maintenance Free |
Number of batteries | 32 |
Float charging voltage | 432 VDC |
End of discharge voltage | 320 VDC |
Battery ambient temperature | 25ºC |
Battery protection | Automatic circuit breaker |
Battery test | Automatic every 72 hours |
GENERAL
Standards | EN 62040-1,EN62040-2 |
Serial communication | Dry contacts & RS232 |
Software | T-Mon UPS Management Software (3 clients, +1 server management std.) |
Temperature range | 0ºC - 40ºC |
Ventilation | Forced air cooling |
Relative humidity | < %90 (non-condensing) |
Protection degree | IP20 |
Altitude | < 2000m above sea level |
Acoustic noise | 70 dBA |
Weight without batteries (kg) | 1328 |
Dimensions (mm) HxWxD | 1880x1565x925 |
OPTIONS
Different input / output voltage | Please ask |
Input transformer | Galvanic isolation transformer at the input (in external cabinet) |
Input THD | 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range) 5% (with 18 Pulse rectifier, + filter), up to 100kVA |
Input power factor | 0,95 - 0,98 (with 18 Pulse rectifier) |
Adaptors | SNMP, MODBUS, Remote Mon. Panel, RS485 |
Parallel operation | N + 1 (up to 4 units) |
(*): | In 18Pulse & 12Pulse applications, the standard chassis dimensions may change. |
MODEL
Power (kVA) | 300 |
INPUT
Voltage | 380/400 VAC 3P + N + G ± 15% |
By-pass voltage | 380/400 VAC 3P + N ± 10% |
Input frequency | 50Hz (60Hz on request) ± 5% |
OUTPUT
Power (kW) | 240 |
Power factor | 0,8 |
Voltage | 380/400 VAC 3P + N |
Voltage stability | Balanced load: ± 1%, Unbalanced load: ± 2%, Step load: ± 5% |
Voltage recovery time | After step load: max. 25ms |
Frequency | 50Hz (60Hz on request) |
Frequency tolerance | Line synchronized: ± 2% , free running: ± 0,2% |
Efficiency (at 100% load) | 90-92% |
Crest factor | 3:1 |
Overload protection | 100%-125% load: 10 min., 125%-150% load: 1 min., >150% load: by pass |
Short circuit protection | Electronic short circuit protection |
Voltage THD | Linear load: < 3% Non linear load: < 5% |
BATTERIES
Type | Sealed Lead Acid - Maintenance Free |
Number of batteries | 32 |
Float charging voltage | 432 VDC |
End of discharge voltage | 320 VDC |
Battery ambient temperature | 25ºC |
Battery protection | Automatic circuit breaker |
Battery test | Automatic every 72 hours |
GENERAL
Standards | EN 62040-1,EN62040-2 |
Serial communication | Dry contacts & RS232 |
Software | T-Mon UPS Management Software (3 clients, +1 server management std.) |
Temperature range | 0ºC - 40ºC |
Ventilation | Forced air cooling |
Relative humidity | < %90 (non-condensing) |
Protection degree | IP20 |
Altitude | < 2000m above sea level |
Acoustic noise | 70 dBA |
Weight without batteries (kg) | 1370 |
Dimensions (mm) HxWxD | 1880x1565x925 |
OPTIONS
Different input / output voltage | Please ask |
Input transformer | Galvanic isolation transformer at the input (in external cabinet) |
Input THD | 10% (with 12 Pulse or 18 Pulse rectifier, according to UPS range) 5% (with 18 Pulse rectifier, + filter), up to 100kVA |
Input power factor | 0,95 - 0,98 (with 18 Pulse rectifier) |
Adaptors | SNMP, MODBUS, Remote Mon. Panel, RS485 |
Parallel operation | N + 1 (up to 4 units) |
(*): | In 18Pulse & 12Pulse applications, the standard chassis dimensions may change. |